The Probe and Sensor are used to control temperature where moisture would be a problem i.e. in wet room or bathroom. It can also control floor temperature where overheating would cause damage.

The temperature of an underfloor heating system is controlled via a thermostat that reads the temperature of the room through sensors. With underfloor heating, it’s common for there to be two types of sensor installed, the usual air sensor (in the thermostat itself) as well as an underfloor heating probe, or floor sensor.


Specification

Dimension (unit:mm)
A B C D L
6.5 20 25±5 3±1 As required

NO Material Name Material and Specifications
2-1. Element R25=10KΩ±1% B25/50=3950K±1% DC
2-2. Coating NTC encapsulated using PVC over-mold material (White)
2-3 Cable features

UL2464-22AWG Tin plated copper cable with white PVC flat jacket wire 80℃ 300V

2-4. Wire ends Tinned

Performance

NO Item Sign Test Conditions Min. Nor. Max. Unit
4-1. Resistance at 25℃ R25

Ta=25±0.05℃

PT≦0.1mw

9.9 10.0 10.1
4-2. B Value B25/50 3910.5 3950 3989.5 k
4-3. Dissipation factor σ In still air About 2 mW/℃
4-4. Time response τ In flowing water About 15 sec
4-5. Withstanding Voltage / 1500VAC 2Sec No breakdown Sec
4-6. Insulation Resistance 500VDC ≧100
4-7. Operating temp. range / / -30 / +105

Installation

When installing a floor sensor, you should always follow the manufacturer’s instructions supplied however, there are some general rules that should be applied when installing any underfloor heating probe.
The probe should be placed equal distance between heating wires and should never cross a heating wire.
The probe can be installed either above or below your electric underfloor heating mat.
Areas in which the temperature may be affected such as near external doors or on heating pipes, should be avoided.

Test

During installation, the underfloor heating probe should be tested to ensure it is working correctly. This will be done by the installer. In order to do this, they will use a digital multimeter. A multimeter is an electronic measuring device that can usually measure voltage, resistance and current. In this case, your installer will be measuring resistance (ohms Ω).
To test if the underfloor heating sensor is working correctly, they will attach the multimeter probes to the floor sensor cable. At normal room temperature, the multimeter should read 10kΩ at 25°C. If this is the case your sensor cable is working correctly and the install can be completed.

People who viewed this also viewed

Cylinder Head Underfloor Heating Thermistor 3950K 1% 10K Temperature Sensor With 3M PVC Cable

The Probe and Sensor are used to control temperature where moisture would be a problem i.e. in wet room or bathroom. It can also control floor temperature where overheating would cause damage.

The temperature of an underfloor heating system is controlled via a thermostat that reads the temperature of the room through sensors. With underfloor heating, it’s common for there to be two types of sensor installed, the usual air sensor (in the thermostat itself) as well as an underfloor heating probe, or floor sensor.

White Black Plastic Capsule Tube Probe Cylinder NTC Temperature Sensor for Electric Kettle Coffee Maker

Plastic-encased cylindrical probe temperature sensors are contact-type temperature sensors widely used for medium and low-temperature measurements. Their typical structure encapsulates the core temperature-sensing element, such as an NTC or PTC thermistor, within a cylindrical plastic housing (commonly made of materials such as ABS, PC, and PP), with insulated wires extending from the housing. This design strikes an excellent balance between cost, performance, and ease of use, making it a versatile solution for cost-effective temperature monitoring.

Spa Pool Heater NTC Temperature Thermistor Sensor Replacement for Jandy Zodiac R0456500

The R0456500 Sensor is used to detect the temperature of the pool water entering the heater
This replacement sensor is compatible with Zodiac & Jandy Pool & Spa Electrical Systems
The temperature sensor kit includes Sleeve and Gasket
Affordable and easy to instal
Replaces thermistor that has been damaged, corroded, rusted or failed

297018400 Freezer Refrigerator NTC 10K Temperature Sensor for Electrolux Frigidaire Fridge

This product is manufactured to Fit Frigidaire Appliances. This is not a Frigidaire OEM product. Wholesale Sensors makes high quality OEM replacement products. Any use of the original Manufacturers brand name, part numbers or model designation for this product is made solely for purposes of demonstrating and for identification compatibility and are displayed for descriptive purposes only. Wholesale Sensors does not associate with, imply any affiliation or endorsement by any original equipment manufacturer.